Star Micronics SP2000 Series Manual de usuario Pagina 143

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 147
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 142
– 140 –
APPENDIX
DIP switch 2
The following table shows all the possible settings for the DIP switch. The factory
default settings are ON for switches 2-1 through 2-6 and OFF for switches 2-7
through 2-8.
Switch Function ON OFF
2-1
Baud Rate See table below
2-2
2-3 Data Length 8 bits 7 bits
2-4 Parity Check Disabled Enabled
2-5 Parity Odd Even
2-6 Handshake DTR/DSR XON/XOFF
2-7 Pin 6 (DSR) Reset Signal Enabled Disabled
2-8 Pin 25 (INIT) Reset Signal Enabled Disabled
Baud Rate Switch 2-1 Switch 2-2
1200BPS OFF OFF
2400BPS ON OFF
4800BPS OFF ON
9600BPS ON ON
Vista de pagina 142
1 2 ... 138 139 140 141 142 143 144 145 146 147

Comentarios a estos manuales

Sin comentarios